SWC4 is the product with the highest desalination rate in the seawater desalination film series of Hyde energy company, which is used to treat seawater with different salt content and low water yield TDS. SWC4 has high desalination and boron removal rates and is suitable for desalination applications with high salt content and high water temperature. SWC4 diaphragm can be rolled into two membrane elements, LD and MAX.
When using traditional pretreatment, LD technology ? can reduce colloid pollution, slow down the rise of pressure difference, and prolong the cleaning cycle.
The membrane area of the MAX membrane element is 440 ft2 (40.9 m2), which can save about 10% membrane quantity when using the same water flux design.
A, SWC4 MAX can America Hyde desalination membrane performance parameters:
model |
SWC4 MAX |
||
specifications |
8 inches |
||
performance |
Desalination rate |
nominal |
99.8% |
The minimum |
99.7% |
||
Water rate |
7200gpd (27.3m3/d) |
||
type |
Film material |
Aromatic polyamide composites |
|
structure |
Roll type |
||
Effective membrane area |
440ft2(40.9㎡) |
||
Test condition |
solution |
32000mg/L NaCl |
|
pressure |
800psi(5.5Pa) |
||
The temperature |
77°F(25℃) |
||
The recovery rate of |
10% |
||
pH |
6.5-7.0 |
* the performance parameters are obtained after the system runs steadily for 30 minutes. The actual test conditions may not be exactly the same as the above data, in which case the performance parameters are standardized data based on standard conditions. The deviation of water yield is within ±15 ±15 %%%% %.
Second, the product use and restrictions:
Maximum operating pressure |
1200 psig (8.27MPa) |
The largest water residual chlorine concentration |
<0.1 mg/L |
Maximum inlet temperature |
113 °F (45 °C) |
Operating pH range |
2-11 |
Cleaning PH range |
1-13 |
Maximum inlet turbidity |
1.0 NTU |
The largest water SDI15 |
5.0 |
Maximum inflow |
75gpm (17mm3/h) |
Maximum pressure drop for single membrane elements |
15psi (0.10 MPa) |
This is only a general constraint. For specific projects, more conservative operating parameters can ensure better performance and longer service life. For details, please refer to the relevant technical data of Hyde energy.
Third, the product description:
Disclaimer: the information and data provided herein are in good faith and in lieu of any warranty. All warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, are hereby denied and excluded. The conditions and methods of use of our products are beyond our control. Hyde energy shall not be liable for the results or damages resulting from the use of this information and data. It is the responsibility of the user to determine the suitability of heidner's products for their particular use.